An electrical test pack should help the authorised reviewer find the original evidence for the right circuit, board, asset or installation area. It should never obscure who performed the work or suggest that a document coordinator has approved its safety. Keep electrical testing, certification and interpretation with the appropriately authorised electrical professionals.
Agree the organising level
Start with the project’s circuit, equipment and drawing identifiers. Ask the electrical contractor whether the pack is assembled by board, system, area or commissioning boundary. Use that structure consistently across the contents page, register and folders.
A practical index can contain:
- pack and circuit or equipment identifier;
- location and drawing reference;
- original test-record title, date and revision;
- named issuer or contractor, as shown on the record;
- instrument or supporting-evidence reference, where supplied;
- certificate reference and source link;
- review status and outstanding action.
Only capture details actually present in the supplied evidence. “Not stated—request clarification” is more reliable than completing a blank from another record.
Reconcile identifiers before merging PDFs
In a hypothetical shop fitout, board DB-2 appears as “DB02” on a drawing and “Distribution Board Two” on a test sheet. Ask the contractor to confirm whether those names represent the same asset. Store the agreed mapping and use one navigation label, while preserving the original wording inside the source records.
If an instrument certificate or technician attachment is supplied, link it as supporting material rather than treating its presence as proof that every test was performed correctly. Any relevance or validity assessment belongs to the electrical reviewer.
Make review status unmistakable
Keep “received”, “submitted” and “accepted by authorised reviewer” separate. A signed record may still need a client review, and a client comment may remain open even when the file itself is complete. Maintain one comment log with the reviewer, requested action, response and revised file reference.
At final collation, check readability, page order, source identity and whether every indexed link opens. A combined PDF can aid navigation, but retain the individual originals and a clear method for replacing a revised record.
Queensland’s Electrical Safety Office publishes guidance on testing and the certificates issued by electrical contractors. Refer the contractor to the current official guidance for the applicable obligations. This article describes evidence organisation and does not prescribe electrical testing methods, certificate wording, technical acceptance or safe energisation.